2023-04-08 00:53:24 -03:00
|
|
|
#include "AP_BattMonitor_config.h"
|
|
|
|
|
|
|
|
#if AP_BATTERY_UAVCAN_BATTERYINFO_ENABLED
|
|
|
|
|
|
|
|
#include <AP_HAL/AP_HAL.h>
|
|
|
|
#include "AP_BattMonitor.h"
|
2023-04-08 00:55:39 -03:00
|
|
|
#include "AP_BattMonitor_DroneCAN.h"
|
2023-04-08 00:53:24 -03:00
|
|
|
|
|
|
|
#include <AP_CANManager/AP_CANManager.h>
|
|
|
|
#include <AP_Common/AP_Common.h>
|
|
|
|
#include <GCS_MAVLink/GCS.h>
|
|
|
|
#include <AP_Math/AP_Math.h>
|
|
|
|
#include <AP_DroneCAN/AP_DroneCAN.h>
|
|
|
|
#include <AP_BoardConfig/AP_BoardConfig.h>
|
|
|
|
|
|
|
|
#define LOG_TAG "BattMon"
|
|
|
|
|
|
|
|
extern const AP_HAL::HAL& hal;
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
const AP_Param::GroupInfo AP_BattMonitor_DroneCAN::var_info[] = {
|
2023-04-08 00:53:24 -03:00
|
|
|
|
|
|
|
// @Param: CURR_MULT
|
|
|
|
// @DisplayName: Scales reported power monitor current
|
|
|
|
// @Description: Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications
|
|
|
|
// @Range: .1 10
|
|
|
|
// @User: Advanced
|
2023-04-08 01:09:10 -03:00
|
|
|
AP_GROUPINFO("CURR_MULT", 30, AP_BattMonitor_DroneCAN, _curr_mult, 1.0),
|
2023-04-08 00:53:24 -03:00
|
|
|
|
2024-05-09 13:08:01 -03:00
|
|
|
// Param indexes must be between 30 and 35 to avoid conflict with other battery monitor param tables loaded by pointer
|
2023-04-08 00:53:24 -03:00
|
|
|
|
|
|
|
AP_GROUPEND
|
|
|
|
};
|
|
|
|
|
|
|
|
/// Constructor
|
2023-04-08 01:09:10 -03:00
|
|
|
AP_BattMonitor_DroneCAN::AP_BattMonitor_DroneCAN(AP_BattMonitor &mon, AP_BattMonitor::BattMonitor_State &mon_state, BattMonitor_DroneCAN_Type type, AP_BattMonitor_Params ¶ms) :
|
2023-08-26 01:12:08 -03:00
|
|
|
AP_BattMonitor_Backend(mon, mon_state, params)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
AP_Param::setup_object_defaults(this,var_info);
|
|
|
|
_state.var_info = var_info;
|
|
|
|
|
|
|
|
// starts with not healthy
|
|
|
|
_state.healthy = false;
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::subscribe_msgs(AP_DroneCAN* ap_dronecan)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
if (ap_dronecan == nullptr) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (Canard::allocate_sub_arg_callback(ap_dronecan, &handle_battery_info_trampoline, ap_dronecan->get_driver_index()) == nullptr) {
|
|
|
|
AP_BoardConfig::allocation_error("battinfo_sub");
|
|
|
|
}
|
|
|
|
|
|
|
|
if (Canard::allocate_sub_arg_callback(ap_dronecan, &handle_battery_info_aux_trampoline, ap_dronecan->get_driver_index()) == nullptr) {
|
|
|
|
AP_BoardConfig::allocation_error("battinfo_aux_sub");
|
|
|
|
}
|
|
|
|
|
|
|
|
if (Canard::allocate_sub_arg_callback(ap_dronecan, &handle_mppt_stream_trampoline, ap_dronecan->get_driver_index()) == nullptr) {
|
|
|
|
AP_BoardConfig::allocation_error("mppt_stream_sub");
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
2023-10-24 18:11:22 -03:00
|
|
|
/*
|
|
|
|
match a battery ID to driver serial number
|
|
|
|
when serial number is negative, all batteries are accepted, otherwise it must match
|
|
|
|
*/
|
|
|
|
bool AP_BattMonitor_DroneCAN::match_battery_id(uint8_t instance, uint8_t battery_id)
|
|
|
|
{
|
|
|
|
const auto serial_num = AP::battery().get_serial_number(instance);
|
|
|
|
return serial_num < 0 || serial_num == (int32_t)battery_id;
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:27:51 -03:00
|
|
|
AP_BattMonitor_DroneCAN* AP_BattMonitor_DroneCAN::get_dronecan_backend(AP_DroneCAN* ap_dronecan, uint8_t node_id, uint8_t battery_id)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
if (ap_dronecan == nullptr) {
|
|
|
|
return nullptr;
|
|
|
|
}
|
2023-10-24 18:11:22 -03:00
|
|
|
const auto &batt = AP::battery();
|
|
|
|
for (uint8_t i = 0; i < batt._num_instances; i++) {
|
|
|
|
if (batt.drivers[i] == nullptr ||
|
|
|
|
batt.get_type(i) != AP_BattMonitor::Type::UAVCAN_BatteryInfo) {
|
2023-04-08 00:53:24 -03:00
|
|
|
continue;
|
|
|
|
}
|
2023-10-24 18:11:22 -03:00
|
|
|
AP_BattMonitor_DroneCAN* driver = (AP_BattMonitor_DroneCAN*)batt.drivers[i];
|
2023-04-08 00:53:24 -03:00
|
|
|
if (driver->_ap_dronecan == ap_dronecan && driver->_node_id == node_id && match_battery_id(i, battery_id)) {
|
|
|
|
return driver;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
// find empty uavcan driver
|
2023-10-24 18:11:22 -03:00
|
|
|
for (uint8_t i = 0; i < batt._num_instances; i++) {
|
|
|
|
if (batt.drivers[i] != nullptr &&
|
|
|
|
batt.get_type(i) == AP_BattMonitor::Type::UAVCAN_BatteryInfo &&
|
2023-04-08 00:53:24 -03:00
|
|
|
match_battery_id(i, battery_id)) {
|
|
|
|
|
2023-10-24 18:11:22 -03:00
|
|
|
AP_BattMonitor_DroneCAN* batmon = (AP_BattMonitor_DroneCAN*)batt.drivers[i];
|
2023-04-08 00:53:24 -03:00
|
|
|
if(batmon->_ap_dronecan != nullptr || batmon->_node_id != 0) {
|
|
|
|
continue;
|
|
|
|
}
|
|
|
|
batmon->_ap_dronecan = ap_dronecan;
|
|
|
|
batmon->_node_id = node_id;
|
|
|
|
batmon->_instance = i;
|
|
|
|
batmon->init();
|
|
|
|
AP::can().log_text(AP_CANManager::LOG_INFO,
|
|
|
|
LOG_TAG,
|
|
|
|
"Registered BattMonitor Node %d on Bus %d\n",
|
|
|
|
node_id,
|
|
|
|
ap_dronecan->get_driver_index());
|
|
|
|
return batmon;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
return nullptr;
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::handle_battery_info(const uavcan_equipment_power_BatteryInfo &msg)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
2024-01-04 23:09:29 -04:00
|
|
|
update_interim_state(msg.voltage, msg.current, msg.temperature, msg.state_of_charge_pct, msg.state_of_health_pct);
|
2023-04-08 00:53:24 -03:00
|
|
|
|
|
|
|
WITH_SEMAPHORE(_sem_battmon);
|
|
|
|
_remaining_capacity_wh = msg.remaining_capacity_wh;
|
|
|
|
_full_charge_capacity_wh = msg.full_charge_capacity_wh;
|
2024-01-04 23:09:29 -04:00
|
|
|
|
|
|
|
// consume state of health
|
|
|
|
if (msg.state_of_health_pct != UAVCAN_EQUIPMENT_POWER_BATTERYINFO_STATE_OF_HEALTH_UNKNOWN) {
|
|
|
|
_interim_state.state_of_health_pct = msg.state_of_health_pct;
|
|
|
|
_interim_state.has_state_of_health_pct = true;
|
|
|
|
}
|
2023-04-08 00:53:24 -03:00
|
|
|
}
|
|
|
|
|
2024-01-04 23:09:29 -04:00
|
|
|
void AP_BattMonitor_DroneCAN::update_interim_state(const float voltage, const float current, const float temperature_K, const uint8_t soc, uint8_t soh_pct)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
WITH_SEMAPHORE(_sem_battmon);
|
|
|
|
|
|
|
|
_interim_state.voltage = voltage;
|
|
|
|
_interim_state.current_amps = _curr_mult * current;
|
|
|
|
_soc = soc;
|
|
|
|
|
|
|
|
if (!isnan(temperature_K) && temperature_K > 0) {
|
|
|
|
// Temperature reported from battery in kelvin and stored internally in Celsius.
|
|
|
|
_interim_state.temperature = KELVIN_TO_C(temperature_K);
|
|
|
|
_interim_state.temperature_time = AP_HAL::millis();
|
|
|
|
}
|
|
|
|
|
|
|
|
const uint32_t tnow = AP_HAL::micros();
|
|
|
|
|
2023-11-24 17:24:39 -04:00
|
|
|
if (!_has_battery_info_aux ||
|
|
|
|
!use_CAN_SoC()) {
|
2023-04-08 00:53:24 -03:00
|
|
|
const uint32_t dt_us = tnow - _interim_state.last_time_micros;
|
|
|
|
|
|
|
|
// update total current drawn since startup
|
|
|
|
update_consumed(_interim_state, dt_us);
|
|
|
|
}
|
|
|
|
|
2024-01-04 23:09:29 -04:00
|
|
|
// state of health
|
|
|
|
if (soh_pct != UAVCAN_EQUIPMENT_POWER_BATTERYINFO_STATE_OF_HEALTH_UNKNOWN) {
|
|
|
|
_interim_state.state_of_health_pct = soh_pct;
|
|
|
|
_interim_state.has_state_of_health_pct = true;
|
|
|
|
}
|
|
|
|
|
2023-04-08 00:53:24 -03:00
|
|
|
// record time
|
|
|
|
_interim_state.last_time_micros = tnow;
|
|
|
|
_interim_state.healthy = true;
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::handle_battery_info_aux(const ardupilot_equipment_power_BatteryInfoAux &msg)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
WITH_SEMAPHORE(_sem_battmon);
|
|
|
|
uint8_t cell_count = MIN(ARRAY_SIZE(_interim_state.cell_voltages.cells), msg.voltage_cell.len);
|
|
|
|
|
|
|
|
_cycle_count = msg.cycle_count;
|
|
|
|
for (uint8_t i = 0; i < cell_count; i++) {
|
|
|
|
_interim_state.cell_voltages.cells[i] = msg.voltage_cell.data[i] * 1000;
|
|
|
|
}
|
|
|
|
_interim_state.is_powering_off = msg.is_powering_off;
|
2023-10-28 00:54:42 -03:00
|
|
|
if (!isnan(msg.nominal_voltage) && msg.nominal_voltage > 0) {
|
|
|
|
float remaining_capacity_ah = _remaining_capacity_wh / msg.nominal_voltage;
|
|
|
|
float full_charge_capacity_ah = _full_charge_capacity_wh / msg.nominal_voltage;
|
|
|
|
_interim_state.consumed_mah = (full_charge_capacity_ah - remaining_capacity_ah) * 1000;
|
|
|
|
_interim_state.consumed_wh = _full_charge_capacity_wh - _remaining_capacity_wh;
|
|
|
|
_interim_state.time_remaining = is_zero(_interim_state.current_amps) ? 0 : (remaining_capacity_ah / _interim_state.current_amps * 3600);
|
|
|
|
_interim_state.has_time_remaining = true;
|
|
|
|
}
|
2023-04-08 00:53:24 -03:00
|
|
|
|
|
|
|
_has_cell_voltages = true;
|
|
|
|
_has_battery_info_aux = true;
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::handle_mppt_stream(const mppt_Stream &msg)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
const bool use_input_value = option_is_set(AP_BattMonitor_Params::Options::MPPT_Use_Input_Value);
|
|
|
|
const float voltage = use_input_value ? msg.input_voltage : msg.output_voltage;
|
|
|
|
const float current = use_input_value ? msg.input_current : msg.output_current;
|
|
|
|
|
|
|
|
// use an invalid soc so we use the library calculated one
|
|
|
|
const uint8_t soc = 127;
|
|
|
|
|
|
|
|
// convert C to Kelvin
|
|
|
|
const float temperature_K = isnan(msg.temperature) ? 0 : C_TO_KELVIN(msg.temperature);
|
|
|
|
|
2024-01-04 23:09:29 -04:00
|
|
|
update_interim_state(voltage, current, temperature_K, soc, UAVCAN_EQUIPMENT_POWER_BATTERYINFO_STATE_OF_HEALTH_UNKNOWN);
|
2023-04-08 00:53:24 -03:00
|
|
|
|
|
|
|
if (!_mppt.is_detected) {
|
|
|
|
// this is the first time the mppt message has been received
|
|
|
|
// so set powered up state
|
|
|
|
_mppt.is_detected = true;
|
|
|
|
|
|
|
|
// Boot/Power-up event
|
|
|
|
if (option_is_set(AP_BattMonitor_Params::Options::MPPT_Power_On_At_Boot)) {
|
|
|
|
mppt_set_powered_state(true);
|
|
|
|
} else if (option_is_set(AP_BattMonitor_Params::Options::MPPT_Power_Off_At_Boot)) {
|
|
|
|
mppt_set_powered_state(false);
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
#if AP_BATTMONITOR_UAVCAN_MPPT_DEBUG
|
|
|
|
if (_mppt.fault_flags != msg.fault_flags) {
|
|
|
|
mppt_report_faults(_instance, msg.fault_flags);
|
|
|
|
}
|
|
|
|
#endif
|
|
|
|
_mppt.fault_flags = msg.fault_flags;
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::handle_battery_info_trampoline(AP_DroneCAN *ap_dronecan, const CanardRxTransfer& transfer, const uavcan_equipment_power_BatteryInfo &msg)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
2023-04-08 01:27:51 -03:00
|
|
|
AP_BattMonitor_DroneCAN* driver = get_dronecan_backend(ap_dronecan, transfer.source_node_id, msg.battery_id);
|
2023-04-08 00:53:24 -03:00
|
|
|
if (driver == nullptr) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
driver->handle_battery_info(msg);
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::handle_battery_info_aux_trampoline(AP_DroneCAN *ap_dronecan, const CanardRxTransfer& transfer, const ardupilot_equipment_power_BatteryInfoAux &msg)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
2023-10-24 18:31:50 -03:00
|
|
|
const auto &batt = AP::battery();
|
|
|
|
AP_BattMonitor_DroneCAN *driver = nullptr;
|
|
|
|
|
|
|
|
/*
|
|
|
|
check for a backend with AllowSplitAuxInfo set, allowing InfoAux
|
|
|
|
from a different CAN node than the base battery information
|
|
|
|
*/
|
|
|
|
for (uint8_t i = 0; i < batt._num_instances; i++) {
|
|
|
|
const auto *drv = batt.drivers[i];
|
|
|
|
if (drv != nullptr &&
|
|
|
|
batt.get_type(i) == AP_BattMonitor::Type::UAVCAN_BatteryInfo &&
|
|
|
|
drv->option_is_set(AP_BattMonitor_Params::Options::AllowSplitAuxInfo) &&
|
|
|
|
batt.get_serial_number(i) == int32_t(msg.battery_id)) {
|
|
|
|
driver = (AP_BattMonitor_DroneCAN *)batt.drivers[i];
|
|
|
|
if (driver->_ap_dronecan == nullptr) {
|
|
|
|
/* we have not received the main battery information
|
|
|
|
yet. Discard InfoAux until we do so we can init the
|
|
|
|
backend with the right node ID
|
|
|
|
*/
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
if (driver == nullptr) {
|
|
|
|
driver = get_dronecan_backend(ap_dronecan, transfer.source_node_id, msg.battery_id);
|
|
|
|
}
|
2023-04-08 00:53:24 -03:00
|
|
|
if (driver == nullptr) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
driver->handle_battery_info_aux(msg);
|
|
|
|
}
|
|
|
|
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::handle_mppt_stream_trampoline(AP_DroneCAN *ap_dronecan, const CanardRxTransfer& transfer, const mppt_Stream &msg)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
2023-04-08 01:27:51 -03:00
|
|
|
AP_BattMonitor_DroneCAN* driver = get_dronecan_backend(ap_dronecan, transfer.source_node_id, transfer.source_node_id);
|
2023-04-08 00:53:24 -03:00
|
|
|
if (driver == nullptr) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
driver->handle_mppt_stream(msg);
|
|
|
|
}
|
|
|
|
|
|
|
|
// read - read the voltage and current
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::read()
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
uint32_t tnow = AP_HAL::micros();
|
|
|
|
|
|
|
|
// timeout after 5 seconds
|
|
|
|
if ((tnow - _interim_state.last_time_micros) > AP_BATTMONITOR_UAVCAN_TIMEOUT_MICROS) {
|
|
|
|
_interim_state.healthy = false;
|
|
|
|
}
|
|
|
|
// Copy over relevant states over to main state
|
|
|
|
WITH_SEMAPHORE(_sem_battmon);
|
|
|
|
_state.temperature = _interim_state.temperature;
|
|
|
|
_state.temperature_time = _interim_state.temperature_time;
|
|
|
|
_state.voltage = _interim_state.voltage;
|
|
|
|
_state.current_amps = _interim_state.current_amps;
|
|
|
|
_state.consumed_mah = _interim_state.consumed_mah;
|
|
|
|
_state.consumed_wh = _interim_state.consumed_wh;
|
|
|
|
_state.last_time_micros = _interim_state.last_time_micros;
|
|
|
|
_state.healthy = _interim_state.healthy;
|
|
|
|
_state.time_remaining = _interim_state.time_remaining;
|
|
|
|
_state.has_time_remaining = _interim_state.has_time_remaining;
|
|
|
|
_state.is_powering_off = _interim_state.is_powering_off;
|
2024-01-04 23:09:29 -04:00
|
|
|
_state.state_of_health_pct = _interim_state.state_of_health_pct;
|
|
|
|
_state.has_state_of_health_pct = _interim_state.has_state_of_health_pct;
|
2023-04-08 00:53:24 -03:00
|
|
|
memcpy(_state.cell_voltages.cells, _interim_state.cell_voltages.cells, sizeof(_state.cell_voltages));
|
|
|
|
|
|
|
|
_has_temperature = (AP_HAL::millis() - _state.temperature_time) <= AP_BATT_MONITOR_TIMEOUT;
|
|
|
|
|
|
|
|
// check if MPPT should be powered on/off depending upon arming state
|
|
|
|
if (_mppt.is_detected) {
|
|
|
|
mppt_check_powered_state();
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
2023-06-23 19:40:05 -03:00
|
|
|
// Return true if the DroneCAN state of charge should be used.
|
|
|
|
// Return false if state of charge should be calculated locally by counting mah.
|
|
|
|
bool AP_BattMonitor_DroneCAN::use_CAN_SoC() const
|
|
|
|
{
|
|
|
|
// a UAVCAN battery monitor may not be able to supply a state of charge. If it can't then
|
|
|
|
// the user can set the option to use current integration in the backend instead.
|
|
|
|
// SOC of 127 is used as an invalid SOC flag ie system configuration errors or SOC estimation unavailable
|
|
|
|
return !(option_is_set(AP_BattMonitor_Params::Options::Ignore_UAVCAN_SoC) ||
|
|
|
|
_mppt.is_detected ||
|
|
|
|
(_soc == 127));
|
|
|
|
}
|
|
|
|
|
2023-04-08 00:53:24 -03:00
|
|
|
/// capacity_remaining_pct - returns true if the percentage is valid and writes to percentage argument
|
2023-04-08 01:09:10 -03:00
|
|
|
bool AP_BattMonitor_DroneCAN::capacity_remaining_pct(uint8_t &percentage) const
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
2023-06-23 19:40:05 -03:00
|
|
|
if (!use_CAN_SoC()) {
|
2023-04-08 00:53:24 -03:00
|
|
|
return AP_BattMonitor_Backend::capacity_remaining_pct(percentage);
|
|
|
|
}
|
|
|
|
|
|
|
|
// the monitor must have current readings in order to estimate consumed_mah and be healthy
|
|
|
|
if (!has_current() || !_state.healthy) {
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
percentage = _soc;
|
|
|
|
return true;
|
|
|
|
}
|
|
|
|
|
2023-06-23 19:40:05 -03:00
|
|
|
// reset remaining percentage to given value
|
|
|
|
bool AP_BattMonitor_DroneCAN::reset_remaining(float percentage)
|
|
|
|
{
|
|
|
|
if (use_CAN_SoC()) {
|
|
|
|
// Cannot reset external state of charge
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
WITH_SEMAPHORE(_sem_battmon);
|
|
|
|
|
|
|
|
if (!AP_BattMonitor_Backend::reset_remaining(percentage)) {
|
|
|
|
// Base class reset failed
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
// Reset interim state that is used internally, this is then copied back to the main state in the read() call
|
|
|
|
_interim_state.consumed_mah = _state.consumed_mah;
|
|
|
|
_interim_state.consumed_wh = _state.consumed_wh;
|
|
|
|
return true;
|
|
|
|
}
|
|
|
|
|
2023-04-08 00:53:24 -03:00
|
|
|
/// get_cycle_count - return true if cycle count can be provided and fills in cycles argument
|
2023-04-08 01:09:10 -03:00
|
|
|
bool AP_BattMonitor_DroneCAN::get_cycle_count(uint16_t &cycles) const
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
if (_has_battery_info_aux) {
|
|
|
|
cycles = _cycle_count;
|
|
|
|
return true;
|
|
|
|
}
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
// request MPPT board to power on/off depending upon vehicle arming state as specified by BATT_OPTIONS
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::mppt_check_powered_state()
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
if ((_mppt.powered_state_remote_ms != 0) && (AP_HAL::millis() - _mppt.powered_state_remote_ms >= 1000)) {
|
|
|
|
// there's already a set attempt that didnt' respond. Retry at 1Hz
|
|
|
|
mppt_set_powered_state(_mppt.powered_state);
|
|
|
|
}
|
|
|
|
|
|
|
|
// check if vehicle armed state has changed
|
|
|
|
const bool vehicle_armed = hal.util->get_soft_armed();
|
|
|
|
if ((!_mppt.vehicle_armed_last && vehicle_armed) && option_is_set(AP_BattMonitor_Params::Options::MPPT_Power_On_At_Arm)) {
|
|
|
|
// arm event
|
|
|
|
mppt_set_powered_state(true);
|
|
|
|
} else if ((_mppt.vehicle_armed_last && !vehicle_armed) && option_is_set(AP_BattMonitor_Params::Options::MPPT_Power_Off_At_Disarm)) {
|
|
|
|
// disarm event
|
|
|
|
mppt_set_powered_state(false);
|
|
|
|
}
|
|
|
|
_mppt.vehicle_armed_last = vehicle_armed;
|
|
|
|
}
|
|
|
|
|
|
|
|
// request MPPT board to power on or off
|
|
|
|
// power_on should be true to power on the MPPT, false to power off
|
|
|
|
// force should be true to force sending the state change request to the MPPT
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::mppt_set_powered_state(bool power_on)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
if (_ap_dronecan == nullptr || !_mppt.is_detected) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
_mppt.powered_state = power_on;
|
|
|
|
|
|
|
|
GCS_SEND_TEXT(MAV_SEVERITY_INFO, "Battery %u: powering %s%s", (unsigned)_instance+1, _mppt.powered_state ? "ON" : "OFF",
|
|
|
|
(_mppt.powered_state_remote_ms == 0) ? "" : " Retry");
|
|
|
|
|
|
|
|
mppt_OutputEnableRequest request;
|
|
|
|
request.enable = _mppt.powered_state;
|
|
|
|
request.disable = !request.enable;
|
|
|
|
|
|
|
|
if (mppt_outputenable_client == nullptr) {
|
2024-05-26 22:24:09 -03:00
|
|
|
mppt_outputenable_client = NEW_NOTHROW Canard::Client<mppt_OutputEnableResponse>{_ap_dronecan->get_canard_iface(), mppt_outputenable_res_cb};
|
2023-04-08 00:53:24 -03:00
|
|
|
if (mppt_outputenable_client == nullptr) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
mppt_outputenable_client->request(_node_id, request);
|
|
|
|
}
|
|
|
|
|
|
|
|
// callback from outputEnable to verify it is enabled or disabled
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::handle_outputEnable_response(const CanardRxTransfer& transfer, const mppt_OutputEnableResponse& response)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
if (transfer.source_node_id != _node_id) {
|
|
|
|
// this response is not from the node we are looking for
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (response.enabled == _mppt.powered_state) {
|
|
|
|
// we got back what we expected it to be. We set it on, it now says it on (or vice versa).
|
|
|
|
// Clear the timer so we don't re-request
|
|
|
|
_mppt.powered_state_remote_ms = 0;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
#if AP_BATTMONITOR_UAVCAN_MPPT_DEBUG
|
|
|
|
// report changes in MPPT faults
|
2023-04-08 01:09:10 -03:00
|
|
|
void AP_BattMonitor_DroneCAN::mppt_report_faults(const uint8_t instance, const uint8_t fault_flags)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
// handle recovery
|
|
|
|
if (fault_flags == 0) {
|
|
|
|
GCS_SEND_TEXT(MAV_SEVERITY_INFO, "Battery %u: OK", (unsigned)instance+1);
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
// send battery faults via text messages
|
|
|
|
for (uint8_t fault_bit=0x01; fault_bit <= 0x08; fault_bit <<= 1) {
|
|
|
|
// this loop is to generate multiple messages if there are multiple concurrent faults, but also run once if there are no faults
|
|
|
|
if ((fault_bit & fault_flags) != 0) {
|
|
|
|
const MPPT_FaultFlags err = (MPPT_FaultFlags)fault_bit;
|
|
|
|
GCS_SEND_TEXT(MAV_SEVERITY_INFO, "Battery %u: %s", (unsigned)instance+1, mppt_fault_string(err));
|
|
|
|
}
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
// returns string description of MPPT fault bit. Only handles single bit faults
|
2023-04-08 01:09:10 -03:00
|
|
|
const char* AP_BattMonitor_DroneCAN::mppt_fault_string(const MPPT_FaultFlags fault)
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
switch (fault) {
|
|
|
|
case MPPT_FaultFlags::OVER_VOLTAGE:
|
|
|
|
return "over voltage";
|
|
|
|
case MPPT_FaultFlags::UNDER_VOLTAGE:
|
|
|
|
return "under voltage";
|
|
|
|
case MPPT_FaultFlags::OVER_CURRENT:
|
|
|
|
return "over current";
|
|
|
|
case MPPT_FaultFlags::OVER_TEMPERATURE:
|
|
|
|
return "over temp";
|
|
|
|
}
|
|
|
|
return "unknown";
|
|
|
|
}
|
|
|
|
#endif
|
|
|
|
|
|
|
|
// return mavlink fault bitmask (see MAV_BATTERY_FAULT enum)
|
2023-04-08 01:09:10 -03:00
|
|
|
uint32_t AP_BattMonitor_DroneCAN::get_mavlink_fault_bitmask() const
|
2023-04-08 00:53:24 -03:00
|
|
|
{
|
|
|
|
// return immediately if not mppt or no faults
|
|
|
|
if (!_mppt.is_detected || (_mppt.fault_flags == 0)) {
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
// convert mppt fault bitmask to mavlink fault bitmask
|
|
|
|
uint32_t mav_fault_bitmask = 0;
|
|
|
|
if ((_mppt.fault_flags & (uint8_t)MPPT_FaultFlags::OVER_VOLTAGE) || (_mppt.fault_flags & (uint8_t)MPPT_FaultFlags::UNDER_VOLTAGE)) {
|
|
|
|
mav_fault_bitmask |= MAV_BATTERY_FAULT_INCOMPATIBLE_VOLTAGE;
|
|
|
|
}
|
|
|
|
if (_mppt.fault_flags & (uint8_t)MPPT_FaultFlags::OVER_CURRENT) {
|
|
|
|
mav_fault_bitmask |= MAV_BATTERY_FAULT_OVER_CURRENT;
|
|
|
|
}
|
|
|
|
if (_mppt.fault_flags & (uint8_t)MPPT_FaultFlags::OVER_TEMPERATURE) {
|
|
|
|
mav_fault_bitmask |= MAV_BATTERY_FAULT_OVER_TEMPERATURE;
|
|
|
|
}
|
|
|
|
return mav_fault_bitmask;
|
|
|
|
}
|
|
|
|
|
|
|
|
#endif // AP_BATTERY_UAVCAN_BATTERYINFO_ENABLED
|