2014-12-04 01:36:17 -04:00
|
|
|
/*
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
|
|
it under the terms of the GNU General Public License as published by
|
|
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
|
|
(at your option) any later version.
|
|
|
|
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
|
|
GNU General Public License for more details.
|
|
|
|
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
*/
|
2016-02-17 21:25:15 -04:00
|
|
|
#pragma once
|
2014-12-04 01:36:17 -04:00
|
|
|
|
2015-08-11 03:28:42 -03:00
|
|
|
#include <AP_Common/AP_Common.h>
|
|
|
|
#include <AP_HAL/AP_HAL.h>
|
2014-12-04 01:36:17 -04:00
|
|
|
#include "AP_BattMonitor.h"
|
|
|
|
|
|
|
|
class AP_BattMonitor_Backend
|
|
|
|
{
|
|
|
|
public:
|
|
|
|
// constructor. This incorporates initialisation as well.
|
2017-10-27 02:36:49 -03:00
|
|
|
AP_BattMonitor_Backend(AP_BattMonitor &mon, AP_BattMonitor::BattMonitor_State &mon_state, AP_BattMonitor_Params ¶ms);
|
2014-12-04 01:36:17 -04:00
|
|
|
|
|
|
|
// we declare a virtual destructor so that BattMonitor driver can
|
|
|
|
// override with a custom destructor if need be
|
|
|
|
virtual ~AP_BattMonitor_Backend(void) {}
|
|
|
|
|
2015-04-09 02:37:15 -03:00
|
|
|
// initialise
|
2021-04-22 17:04:45 -03:00
|
|
|
virtual void init() {};
|
2015-04-09 02:37:15 -03:00
|
|
|
|
2014-12-04 01:36:17 -04:00
|
|
|
// read the latest battery voltage
|
|
|
|
virtual void read() = 0;
|
|
|
|
|
2021-10-11 04:25:04 -03:00
|
|
|
/// returns true if battery monitor instance provides time remaining info
|
|
|
|
virtual bool has_time_remaining() const { return false; }
|
|
|
|
|
2016-08-25 09:53:33 -03:00
|
|
|
/// returns true if battery monitor instance provides consumed energy info
|
|
|
|
virtual bool has_consumed_energy() const { return false; }
|
|
|
|
|
2017-05-24 04:43:10 -03:00
|
|
|
/// returns true if battery monitor instance provides current info
|
|
|
|
virtual bool has_current() const = 0;
|
|
|
|
|
2017-05-31 00:31:18 -03:00
|
|
|
// returns true if battery monitor provides individual cell voltages
|
|
|
|
virtual bool has_cell_voltages() const { return false; }
|
|
|
|
|
2021-01-07 22:11:56 -04:00
|
|
|
// returns true if battery monitor provides temperature
|
|
|
|
virtual bool has_temperature() const { return false; }
|
|
|
|
|
2021-09-23 01:57:41 -03:00
|
|
|
// capacity_remaining_pct - returns true if the battery % is available and writes to the percentage argument
|
|
|
|
// returns false if the battery is unhealthy, does not have current monitoring, or the pack_capacity is too small
|
2020-04-23 13:17:09 -03:00
|
|
|
virtual bool capacity_remaining_pct(uint8_t &percentage) const WARN_IF_UNUSED;
|
2014-12-04 01:36:17 -04:00
|
|
|
|
2019-12-10 20:55:20 -04:00
|
|
|
// return true if cycle count can be provided and fills in cycles argument
|
|
|
|
virtual bool get_cycle_count(uint16_t &cycles) const { return false; }
|
|
|
|
|
2018-09-12 18:18:06 -03:00
|
|
|
/// get voltage with sag removed (based on battery current draw and resistance)
|
|
|
|
/// this will always be greater than or equal to the raw voltage
|
|
|
|
float voltage_resting_estimate() const;
|
|
|
|
|
2017-05-23 04:12:58 -03:00
|
|
|
// update battery resistance estimate and voltage_resting_estimate
|
|
|
|
void update_resistance_estimate();
|
|
|
|
|
2018-09-12 18:18:06 -03:00
|
|
|
// updates failsafe timers, and returns what failsafes are active
|
2020-10-22 22:33:03 -03:00
|
|
|
virtual AP_BattMonitor::Failsafe update_failsafes(void);
|
2018-09-12 18:18:06 -03:00
|
|
|
|
2018-09-12 19:26:39 -03:00
|
|
|
// returns false if we fail arming checks, in which case the buffer will be populated with a failure message
|
|
|
|
bool arming_checks(char * buffer, size_t buflen) const;
|
|
|
|
|
2019-06-18 06:30:18 -03:00
|
|
|
// reset remaining percentage to given value
|
|
|
|
virtual bool reset_remaining(float percentage);
|
|
|
|
|
2021-12-06 09:32:49 -04:00
|
|
|
// return mavlink fault bitmask (see MAV_BATTERY_FAULT enum)
|
|
|
|
virtual uint32_t get_mavlink_fault_bitmask() const { return 0; }
|
|
|
|
|
2021-01-06 20:51:50 -04:00
|
|
|
// logging functions
|
|
|
|
void Log_Write_BAT(const uint8_t instance, const uint64_t time_us) const;
|
|
|
|
void Log_Write_BCL(const uint8_t instance, const uint64_t time_us) const;
|
|
|
|
|
2021-12-16 14:48:09 -04:00
|
|
|
// amps: current (A)
|
|
|
|
// dt_us: time between samples (micro-seconds)
|
|
|
|
static float calculate_mah(float amps, float dt_us) { return (float) (amps * dt_us * AUS_TO_MAH); }
|
|
|
|
|
2014-12-04 01:36:17 -04:00
|
|
|
protected:
|
|
|
|
AP_BattMonitor &_mon; // reference to front-end
|
|
|
|
AP_BattMonitor::BattMonitor_State &_state; // reference to this instances state (held in the front-end)
|
2017-10-27 02:36:49 -03:00
|
|
|
AP_BattMonitor_Params &_params; // reference to this instances parameters (held in the front-end)
|
2017-05-23 04:12:58 -03:00
|
|
|
|
2018-09-12 18:26:34 -03:00
|
|
|
// checks what failsafes could be triggered
|
|
|
|
void check_failsafe_types(bool &low_voltage, bool &low_capacity, bool &critical_voltage, bool &critical_capacity) const;
|
|
|
|
|
2017-05-23 04:12:58 -03:00
|
|
|
private:
|
|
|
|
// resistance estimate
|
|
|
|
uint32_t _resistance_timer_ms; // system time of last resistance estimate update
|
|
|
|
float _voltage_filt; // filtered voltage
|
|
|
|
float _current_max_amps; // maximum current since start-up
|
|
|
|
float _current_filt_amps; // filtered current
|
|
|
|
float _resistance_voltage_ref; // voltage used for maximum resistance calculation
|
|
|
|
float _resistance_current_ref; // current used for maximum resistance calculation
|
2014-12-04 01:36:17 -04:00
|
|
|
};
|