187 lines
7.7 KiB
ReStructuredText
187 lines
7.7 KiB
ReStructuredText
|
|
:mod:`signal` --- Set handlers for asynchronous events
|
|
======================================================
|
|
|
|
.. module:: signal
|
|
:synopsis: Set handlers for asynchronous events.
|
|
|
|
|
|
This module provides mechanisms to use signal handlers in Python. Some general
|
|
rules for working with signals and their handlers:
|
|
|
|
* A handler for a particular signal, once set, remains installed until it is
|
|
explicitly reset (Python emulates the BSD style interface regardless of the
|
|
underlying implementation), with the exception of the handler for
|
|
:const:`SIGCHLD`, which follows the underlying implementation.
|
|
|
|
* There is no way to "block" signals temporarily from critical sections (since
|
|
this is not supported by all Unix flavors).
|
|
|
|
* Although Python signal handlers are called asynchronously as far as the Python
|
|
user is concerned, they can only occur between the "atomic" instructions of the
|
|
Python interpreter. This means that signals arriving during long calculations
|
|
implemented purely in C (such as regular expression matches on large bodies of
|
|
text) may be delayed for an arbitrary amount of time.
|
|
|
|
* When a signal arrives during an I/O operation, it is possible that the I/O
|
|
operation raises an exception after the signal handler returns. This is
|
|
dependent on the underlying Unix system's semantics regarding interrupted system
|
|
calls.
|
|
|
|
* Because the C signal handler always returns, it makes little sense to catch
|
|
synchronous errors like :const:`SIGFPE` or :const:`SIGSEGV`.
|
|
|
|
* Python installs a small number of signal handlers by default: :const:`SIGPIPE`
|
|
is ignored (so write errors on pipes and sockets can be reported as ordinary
|
|
Python exceptions) and :const:`SIGINT` is translated into a
|
|
:exc:`KeyboardInterrupt` exception. All of these can be overridden.
|
|
|
|
* Some care must be taken if both signals and threads are used in the same
|
|
program. The fundamental thing to remember in using signals and threads
|
|
simultaneously is: always perform :func:`signal` operations in the main thread
|
|
of execution. Any thread can perform an :func:`alarm`, :func:`getsignal`, or
|
|
:func:`pause`; only the main thread can set a new signal handler, and the main
|
|
thread will be the only one to receive signals (this is enforced by the Python
|
|
:mod:`signal` module, even if the underlying thread implementation supports
|
|
sending signals to individual threads). This means that signals can't be used
|
|
as a means of inter-thread communication. Use locks instead.
|
|
|
|
The variables defined in the :mod:`signal` module are:
|
|
|
|
|
|
.. data:: SIG_DFL
|
|
|
|
This is one of two standard signal handling options; it will simply perform the
|
|
default function for the signal. For example, on most systems the default
|
|
action for :const:`SIGQUIT` is to dump core and exit, while the default action
|
|
for :const:`SIGCLD` is to simply ignore it.
|
|
|
|
|
|
.. data:: SIG_IGN
|
|
|
|
This is another standard signal handler, which will simply ignore the given
|
|
signal.
|
|
|
|
|
|
.. data:: SIG*
|
|
|
|
All the signal numbers are defined symbolically. For example, the hangup signal
|
|
is defined as :const:`signal.SIGHUP`; the variable names are identical to the
|
|
names used in C programs, as found in ``<signal.h>``. The Unix man page for
|
|
':cfunc:`signal`' lists the existing signals (on some systems this is
|
|
:manpage:`signal(2)`, on others the list is in :manpage:`signal(7)`). Note that
|
|
not all systems define the same set of signal names; only those names defined by
|
|
the system are defined by this module.
|
|
|
|
|
|
.. data:: NSIG
|
|
|
|
One more than the number of the highest signal number.
|
|
|
|
The :mod:`signal` module defines the following functions:
|
|
|
|
|
|
.. function:: alarm(time)
|
|
|
|
If *time* is non-zero, this function requests that a :const:`SIGALRM` signal be
|
|
sent to the process in *time* seconds. Any previously scheduled alarm is
|
|
canceled (only one alarm can be scheduled at any time). The returned value is
|
|
then the number of seconds before any previously set alarm was to have been
|
|
delivered. If *time* is zero, no alarm is scheduled, and any scheduled alarm is
|
|
canceled. If the return value is zero, no alarm is currently scheduled. (See
|
|
the Unix man page :manpage:`alarm(2)`.) Availability: Unix.
|
|
|
|
|
|
.. function:: getsignal(signalnum)
|
|
|
|
Return the current signal handler for the signal *signalnum*. The returned value
|
|
may be a callable Python object, or one of the special values
|
|
:const:`signal.SIG_IGN`, :const:`signal.SIG_DFL` or :const:`None`. Here,
|
|
:const:`signal.SIG_IGN` means that the signal was previously ignored,
|
|
:const:`signal.SIG_DFL` means that the default way of handling the signal was
|
|
previously in use, and ``None`` means that the previous signal handler was not
|
|
installed from Python.
|
|
|
|
|
|
.. function:: pause()
|
|
|
|
Cause the process to sleep until a signal is received; the appropriate handler
|
|
will then be called. Returns nothing. Not on Windows. (See the Unix man page
|
|
:manpage:`signal(2)`.)
|
|
|
|
|
|
.. function:: set_wakeup_fd(fd)
|
|
|
|
Set the wakeup fd to *fd*. When a signal is received, a ``'\0'`` byte is
|
|
written to the fd. This can be used by a library to wakeup a poll or select
|
|
call, allowing the signal to be fully processed.
|
|
|
|
The old wakeup fd is returned. *fd* must be non-blocking. It is up to the
|
|
library to remove any bytes before calling poll or select again.
|
|
|
|
When threads are enabled, this function can only be called from the main thread;
|
|
attempting to call it from other threads will cause a :exc:`ValueError`
|
|
exception to be raised.
|
|
|
|
|
|
|
|
.. function:: siginterrupt(signalnum, flag)
|
|
|
|
Change system call restart behaviour: if *flag* is :const:`False`, system calls
|
|
will be restarted when interrupted by signal *signalnum*, otherwise system calls will
|
|
be interrupted. Returns nothing. Availability: Unix, Mac (see the man page
|
|
:manpage:`siginterrupt(3)` for further information).
|
|
|
|
Note that installing a signal handler with :func:`signal` will reset the restart
|
|
behaviour to interruptible by implicitly calling :cfunc:`siginterrupt` with a true *flag*
|
|
value for the given signal.
|
|
|
|
.. versionadded:: 2.6
|
|
|
|
|
|
.. function:: signal(signalnum, handler)
|
|
|
|
Set the handler for signal *signalnum* to the function *handler*. *handler* can
|
|
be a callable Python object taking two arguments (see below), or one of the
|
|
special values :const:`signal.SIG_IGN` or :const:`signal.SIG_DFL`. The previous
|
|
signal handler will be returned (see the description of :func:`getsignal`
|
|
above). (See the Unix man page :manpage:`signal(2)`.)
|
|
|
|
When threads are enabled, this function can only be called from the main thread;
|
|
attempting to call it from other threads will cause a :exc:`ValueError`
|
|
exception to be raised.
|
|
|
|
The *handler* is called with two arguments: the signal number and the current
|
|
stack frame (``None`` or a frame object; for a description of frame objects, see
|
|
the reference manual section on the standard type hierarchy or see the attribute
|
|
descriptions in the :mod:`inspect` module).
|
|
|
|
|
|
.. _signal-example:
|
|
|
|
Example
|
|
-------
|
|
|
|
Here is a minimal example program. It uses the :func:`alarm` function to limit
|
|
the time spent waiting to open a file; this is useful if the file is for a
|
|
serial device that may not be turned on, which would normally cause the
|
|
:func:`os.open` to hang indefinitely. The solution is to set a 5-second alarm
|
|
before opening the file; if the operation takes too long, the alarm signal will
|
|
be sent, and the handler raises an exception. ::
|
|
|
|
import signal, os
|
|
|
|
def handler(signum, frame):
|
|
print 'Signal handler called with signal', signum
|
|
raise IOError, "Couldn't open device!"
|
|
|
|
# Set the signal handler and a 5-second alarm
|
|
signal.signal(signal.SIGALRM, handler)
|
|
signal.alarm(5)
|
|
|
|
# This open() may hang indefinitely
|
|
fd = os.open('/dev/ttyS0', os.O_RDWR)
|
|
|
|
signal.alarm(0) # Disable the alarm
|
|
|