Fix test_asyncio timeouts: don't measure the maximum duration, a test
should not measure a CI performance. Only measure the minimum
duration when a task has a timeout or delay. Add CLOCK_RES to
test_asyncio.utils.
Simply closing the event loop isn't enough to avoid warnings. If we
don't also shut down the event loop's default executor, it sometimes
logs a "dangling thread" warning.
Follow-up to GH-22017
Stopping and restarting a proactor event loop on windows can lead to
spurious errors logged (ConnectionResetError while reading from the
self pipe). This fixes the issue by ensuring that we don't attempt
to start multiple copies of the self-pipe reading loop.
Join the thread to prevent leaking a running thread and leaking a
reference.
Cleanup also the test:
* asyncioWindowsProactorEventLoopPolicy became the default policy,
there is no need to set it manually.
* Only start the thread once the loop is running.
* Use a shorter sleep in the thread (100 ms rather than 1 sec).
* Use close_loop(loop) rather than loop.close().
* Use longer variable names.
As in title, expose C `raise` function as `raise_function` in `signal` module. Also drop existing `raise_signal` in `_testcapi` module and replace all usages with new function.
https://bugs.python.org/issue35568
* Convert asyncio/tasks.py to async/await
* Convert asyncio/queues.py to async/await
* Convert asyncio/test_utils.py to async/await
* Convert asyncio/base_subprocess.py to async/await
* Convert asyncio/subprocess.py to async/await
* Convert asyncio/streams.py to async/await
* Fix comments
* Convert asyncio/locks.py to async/await
* Convert asyncio.sleep to async def
* Add a comment
* Add missing news
* Convert stubs from AbstrctEventLoop to async functions
* Convert subprocess_shell/subprocess_exec
* Convert connect_read_pipe/connect_write_pip to async/await syntax
* Convert create_datagram_endpoint
* Convert create_unix_server/create_unix_connection
* Get rid of old style coroutines in unix_events.py
* Convert selector_events.py to async/await
* Convert wait_closed and create_connection
* Drop redundant line
* Convert base_events.py
* Code cleanup
* Drop redundant comments
* Fix indentation
* Add explicit tests for compatibility between old and new coroutines
* Convert windows event loop to use async/await
* Fix double awaiting of async function
* Convert asyncio/locks.py
* Improve docstring
* Convert tests to async/await
* Convert more tests
* Convert more tests
* Convert more tests
* Convert tests
* Improve test
* Remove asyncio.selectors and asyncio._overlapped symbols from the
namespace of the asyncio module
* Replace "from asyncio import selectors" with "import selectors"
* Replace "from asyncio import _overlapped" with "import _overlapped"
asyncio.selectors was added to support Python 3.3, which doesn't have
selectors in its standard library, and Python 3.4 in the same code
base. Same rationale for asyncio._overlapped. Python 3.3 reached its
end of life, and asyncio is no more maintained as a third party
module on PyPI.
Use a coroutine with asyncio.sleep() instead of call_later() to ensure that the
schedule call is cancelled.
Add also a unit test cancelling connect_pipe().
Improve stability of the proactor event loop, especially operations on
overlapped objects:
* Tulip issue 195: Don't call UnregisterWait() twice if a _WaitHandleFuture is
cancelled twice to fix a crash.
* IocpProactor.close(): cancel futures to cancel overlapped operations, instead
of cancelling directly overlapped operations. Future objects may not call
ov.cancel() if the future was cancelled or if the overlapped was already
cancelled. The cancel() method of the future may also catch exceptions. Log
also errors on cancellation.
* tests: rename "f" to "fut"
* Add a __repr__() method to IocpProactor
* Add a destructor to IocpProactor which closes it
* _OverlappedFuture.cancel() doesn't cancel the overlapped anymore if it is
done: if it is already cancelled or completed. Log also an error if the
cancellation failed.
* Add the address of the overlapped object in repr(_OverlappedFuture)
* _OverlappedFuture truncates the source traceback to hide the call to the
parent constructor (useless in debug).
* Add a new asyncio.subprocess module
* Add new create_subprocess_exec() and create_subprocess_shell() functions
* The new asyncio.subprocess.SubprocessStreamProtocol creates stream readers
for stdout and stderr and a stream writer for stdin.
* The new asyncio.subprocess.Process class offers an API close to the
subprocess.Popen class:
- pid, returncode, stdin, stdout and stderr attributes
- communicate(), wait(), send_signal(), terminate() and kill() methods
* Remove STDIN (0), STDOUT (1) and STDERR (2) constants from base_subprocess
and unix_events, to not be confused with the symbols with the same name of
subprocess and asyncio.subprocess modules
* _ProactorBasePipeTransport.get_write_buffer_size() now counts also the size
of the pending write
* _ProactorBaseWritePipeTransport._loop_writing() may now pause the protocol if
the write buffer size is greater than the high water mark (64 KB by default)
Major changes:
- StreamReader.readexactly() now raises an IncompleteReadError if the
end of stream is reached before we received enough bytes, instead of
returning less bytes than requested.
- Unit tests use the main asyncio module instead of submodules like events
- _UnixWritePipeTransport now also supports character devices, as
_UnixReadPipeTransport. Patch written by Jonathan Slenders.
- Export more symbols: BaseEventLoop, BaseProactorEventLoop,
BaseSelectorEventLoop, Queue and Queue sublasses, Empty, Full