* Add docs for new APIs
* Add soft-deprecation notices
* Add What's New porting entries
* Update comments referencing `PyFrame_LocalsToFast()` to mention the proxy instead
* Other related cleanups found when looking for refs to the deprecated APIs
Support non-dict globals in LOAD_FROM_DICT_OR_GLOBALS
The implementation basically copies LOAD_GLOBAL. Possibly it could be deduplicated,
but that seems like it may get hairy since the two operations have different operands.
This is important to fix in 3.14 for PEP 649, but it's a bug in earlier versions too,
and we should backport to 3.13 and 3.12 if possible.
The PEP 649 implementation will require a way to load NotImplementedError
from the bytecode. @markshannon suggested implementing this by converting
LOAD_ASSERTION_ERROR into a more general mechanism for loading constants.
This PR adds this new opcode. I will work on the rest of the implementation
of the PEP separately.
Co-authored-by: Irit Katriel <1055913+iritkatriel@users.noreply.github.com>
* Add CALL_PY_GENERAL, CALL_BOUND_METHOD_GENERAL and call CALL_NON_PY_GENERAL specializations.
* Remove CALL_PY_WITH_DEFAULTS specialization
* Use CALL_NON_PY_GENERAL in more cases when otherwise failing to specialize
The code for Tier 2 is now only compiled when configured
with `--enable-experimental-jit[=yes|interpreter]`.
We drop support for `PYTHON_UOPS` and -`Xuops`,
but you can disable the interpreter or JIT
at runtime by setting `PYTHON_JIT=0`.
You can also build it without enabling it by default
using `--enable-experimental-jit=yes-off`;
enable with `PYTHON_JIT=1`.
On Windows, the `build.bat` script supports
`--experimental-jit`, `--experimental-jit-off`,
`--experimental-interpreter`.
In the C code, `_Py_JIT` is defined as before
when the JIT is enabled; the new variable
`_Py_TIER2` is defined when the JIT *or* the
interpreter is enabled. It is actually a bitmask:
1: JIT; 2: default-off; 4: interpreter.
Makes sys.settrace, sys.setprofile, and monitoring generally thread-safe.
Mostly uses a stop-the-world approach and synchronization around the code object's _co_instrumentation_version. There may be a little bit of extra synchronization around the monitoring data that's required to be TSAN clean.
Introduce a unified 16-bit backoff counter type (``_Py_BackoffCounter``),
shared between the Tier 1 adaptive specializer and the Tier 2 optimizer. The
API used for adaptive specialization counters is changed but the behavior is
(supposed to be) identical.
The behavior of the Tier 2 counters is changed:
- There are no longer dynamic thresholds (we never varied these).
- All counters now use the same exponential backoff.
- The counter for ``JUMP_BACKWARD`` starts counting down from 16.
- The ``temperature`` in side exits starts counting down from 64.
There are now at least two bytecodes that may attempt to optimize,
JUMP_BACK, and more recently, COLD_EXIT.
Only the JUMP_BACK was counting the attempt in the stats.
This moves that counter to uop_optimize itself so it should
always happen no matter where it is called from.
This change adds an `eval_breaker` field to `PyThreadState`. The primary
motivation is for performance in free-threaded builds: with thread-local eval
breakers, we can stop a specific thread (e.g., for an async exception) without
interrupting other threads.
The source of truth for the global instrumentation version is stored in the
`instrumentation_version` field in PyInterpreterState. Threads usually read the
version from their local `eval_breaker`, where it continues to be colocated
with the eval breaker bits.
- Ensure that `assert(type_version != 0);` always comes *before* using `type_version`
Also:
- In cases_generator, rename `-v` to from `--verbose` to `--viable`
- Double max trace size to 256
- Add a dependency on executor_cases.c.h for ceval.o
- Mark `_SPECIALIZE_UNPACK_SEQUENCE` as `TIER_ONE_ONLY`
- Add debug output back showing the optimized trace
- Bunch of cleanups to Tools/cases_generator/
- There is no longer a separate Python/executor.c file.
- Conventions in Python/bytecodes.c are slightly different -- don't use `goto error`,
you must use `GOTO_ERROR(error)` (same for others like `unused_local_error`).
- The `TIER_ONE` and `TIER_TWO` symbols are only valid in the generated (.c.h) files.
- In Lib/test/support/__init__.py, `Py_C_RECURSION_LIMIT` is imported from `_testcapi`.
- On Windows, in debug mode, stack allocation grows from 8MiB to 12MiB.
- **Beware!** This changes the env vars to enable uops and their debugging
to `PYTHON_UOPS` and `PYTHON_LLTRACE`.
In Python/bytecodes.c, you now write
```
DEOPT_IF(condition);
```
The code generator expands this to
```
DEOPT_IF(condition, opcode);
```
where `opcode` is the name of the unspecialized instruction.
This works inside macro expansions too.
**CAVEAT:** The entire `DEOPT_IF(condition)` statement must be on a single line.
If it isn't, the substitution will fail; an error will be printed by the code generator
and the C compiler will report some errors.
These are the most popular specializations of `LOAD_ATTR` and `STORE_ATTR`
that weren't already viable uops:
* Split LOAD_ATTR_METHOD_WITH_VALUES
* Split LOAD_ATTR_METHOD_NO_DICT
* Split LOAD_ATTR_SLOT
* Split STORE_ATTR_SLOT
* Split STORE_ATTR_INSTANCE_VALUE
Also:
* Add `-v` flag to code generator which prints a list of non-viable uops
(easter-egg: it can print execution counts -- see source)
* Double _Py_UOP_MAX_TRACE_LENGTH to 128
I had dropped one of the DEOPT_IF() calls! :-(