This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see .
*/
/*
Simulator for the IntelligentEnergy 2.4kW FuelCell
./Tools/autotest/sim_vehicle.py --gdb --debug -v ArduCopter -A --uartF=sim:ie24 --speedup=1 --console
param set SERIAL5_PROTOCOL 30 # Generator
param set SERIAL5_BAUD 115200
param set GEN_TYPE 2 # IE24
param set BATT3_MONITOR 17 # electrical generator
param set BATT2_MONITOR 18 # fuel-based generator
param set SIM_IE24_ENABLE 1
param fetch
graph BATTERY_STATUS[0].voltages[0]/1000.0
graph BATTERY_STATUS[1].voltages[0]/1000.0
reboot
# TODO: ./Tools/autotest/autotest.py --gdb --debug build.ArduCopter fly.ArduCopter.IntelligentEnergy24
*/
#pragma once
#include
#include "SITL_Input.h"
#include "SIM_IntelligentEnergy.h"
#include
namespace SITL {
class IntelligentEnergy24 : public IntelligentEnergy {
public:
IntelligentEnergy24();
// update state
void update(const struct sitl_input &input) override;
static const AP_Param::GroupInfo var_info[];
private:
void update_send();
const char * get_error_string(const uint32_t code);
AP_Int8 enabled; // enable sim
AP_Int8 set_state;
AP_Int32 err_code;
float battery_voltage = 50.4f;
float bat_capacity_mAh = 3300;
bool discharge = true; // used to switch between battery charging and discharging
uint32_t last_data_sent_ms;
uint32_t last_ver_sent_ms;
};
}