#pragma once #include "AP_Baro_Backend.h" #if AP_BARO_ICP201XX_ENABLED #include #include #include class AP_Baro_ICP201XX : public AP_Baro_Backend { public: void update() override; static AP_Baro_Backend *probe(AP_Baro &baro, AP_HAL::OwnPtr dev); private: AP_Baro_ICP201XX(AP_Baro &baro, AP_HAL::OwnPtr dev); bool init(); void dummy_reg(); bool read_reg(uint8_t reg, uint8_t *buf, uint8_t len); bool read_reg(uint8_t reg, uint8_t *val); bool write_reg(uint8_t reg, uint8_t val); bool mode_select(uint8_t mode); bool read_otp_data(uint8_t addr, uint8_t cmd, uint8_t *val); bool get_sensor_data(float *pressure, float *temperature); void soft_reset(); bool boot_sequence(); bool configure(); void wait_read(); bool flush_fifo(); void timer(); uint8_t instance; AP_HAL::OwnPtr dev; // accumulation structure, protected by _sem struct { float tsum; float psum; uint32_t count; } accum; // time last read command was sent uint32_t last_measure_us; enum class OP_MODE : uint8_t { OP_MODE0 = 0, /* Mode 0: Bw:6.25 Hz ODR: 25Hz */ OP_MODE1, /* Mode 1: Bw:30 Hz ODR: 120Hz */ OP_MODE2, /* Mode 2: Bw:10 Hz ODR: 40Hz */ OP_MODE3, /* Mode 3: Bw:0.5 Hz ODR: 2Hz */ OP_MODE4, /* Mode 4: User configurable Mode */ } _op_mode{OP_MODE::OP_MODE2}; enum class FIFO_READOUT_MODE : uint8_t { FIFO_READOUT_MODE_PRES_TEMP = 0, /* Pressure and temperature as pair and address wraps to the start address of the Pressure value ( pressure first ) */ FIFO_READOUT_MODE_TEMP_ONLY = 1, /* Temperature only reporting */ FIFO_READOUT_MODE_TEMP_PRES = 2, /* Pressure and temperature as pair and address wraps to the start address of the Temperature value ( Temperature first ) */ FIFO_READOUT_MODE_PRES_ONLY = 3 /* Pressure only reporting */ } _fifo_readout_mode{FIFO_READOUT_MODE::FIFO_READOUT_MODE_PRES_TEMP}; enum class POWER_MODE : uint8_t { POWER_MODE_NORMAL = 0, /* Normal Mode: Device is in standby and goes to active mode during the execution of a measurement */ POWER_MODE_ACTIVE = 1 /* Active Mode: Power on DVDD and enable the high frequency clock */ } _power_mode{POWER_MODE::POWER_MODE_NORMAL}; enum MEAS_MODE : uint8_t { MEAS_MODE_FORCED_TRIGGER = 0, /* Force trigger mode based on icp201xx_forced_meas_trigger_t **/ MEAS_MODE_CONTINUOUS = 1 /* Continuous measurements based on selected mode ODR settings*/ } _meas_mode{MEAS_MODE::MEAS_MODE_CONTINUOUS}; enum FORCED_MEAS_TRIGGER : uint8_t { FORCE_MEAS_STANDBY = 0, /* Stay in Stand by */ FORCE_MEAS_TRIGGER_FORCE_MEAS = 1 /* Trigger for forced measurements */ } _forced_meas_trigger{FORCED_MEAS_TRIGGER::FORCE_MEAS_STANDBY}; }; #endif // AP_BARO_ICP201XX_ENABLED