using System; using System.Collections.Generic; using System.ComponentModel; using Timer=System.Windows.Forms.Timer; namespace ArducopterConfigurator.PresentationModels { public class MainVm : NotifyProperyChangedBase, IPresentationModel { private readonly IComms _comms; private bool _isConnected; private IPresentationModel _selectedVm; private string _selectedPort; private int _selectedBaudRate; private string _apmVersion; private Timer _connectionAttemptsTimer; private SessionStates _connectionState; public MainVm(IComms session) { _comms = session; _comms.LineOfDataReceived += _session_LineOfDataReceived; MonitorVms = new BindingList { new SensorsVm(), new TransmitterChannelsVm(), new FlightControlPidsVm(), new PositionAltitudePidsVm(), new GpsStatusVm(), //new MotorCommandsVm(session), new SerialMonitorVm(), }; foreach (var vm in MonitorVms) { if (vm is ItalksToApm) vm.sendTextToApm += MainVm_sendTextToApm; } ConnectCommand = new DelegateCommand( _ => Connect(), _ => _connectionState==SessionStates.Disconnected && AvailablePorts.Contains(SelectedPort)); DisconnectCommand = new DelegateCommand(_ => Disconnect(), _ => IsConnected); RefreshPortListCommand = new DelegateCommand(_ => RefreshPorts()); RestoreDefaultsCommand = new DelegateCommand(_ => RestoreDefaults(), _ => IsConnected); WriteToEepromCommand = new DelegateCommand(_ => WriteToEeprom(), _ => IsConnected); ConnectionState = SessionStates.Disconnected; AvailablePorts = new BindingList(); AvailableBaudRates = new BindingList() {115200, 57600, 38400, 9600}; SelectedBaudRate = 115200; RefreshPorts(); // Initially have selected the last discovered com port. // I think this is more likely to be the correct one, as // the built in comports come first, then the usb/serial // converter ports if (AvailablePorts.Count > 0) SelectedPort = AvailablePorts[AvailablePorts.Count-1]; } void MainVm_sendTextToApm(object sender, sendTextToApmEventArgs e) { if (sender.Equals(_selectedVm)==false) { Console.WriteLine("Non selected vm wants to send something to the APM"); return; } if (_comms.IsConnected) _comms.Send(e.textToSend); } private void RefreshPorts() { AvailablePorts.Clear(); foreach (var c in _comms.ListCommPorts()) AvailablePorts.Add(c); } private void RestoreDefaults() { if (_comms.IsConnected) _comms.Send("Y"); } private void WriteToEeprom() { if (_comms.IsConnected) _comms.Send("W"); } void _session_LineOfDataReceived(string strRx) { // If we are waiting for the version string if (ConnectionState==SessionStates.Connecting) { if (strRx.Length > 6) return; // too long for a version string - reject // then assume that this is the version string received ApmVersion = strRx; ConnectionState = SessionStates.Connected; _selectedVm.Activate(); } else if (ConnectionState == SessionStates.Connected) { if (_selectedVm is ItalksToApm) (_selectedVm as ItalksToApm).handleLineOfText(strRx); } } public ICommand ConnectCommand { get; private set; } public ICommand DisconnectCommand { get; private set; } public ICommand RefreshPortListCommand { get; private set; } public ICommand RestoreDefaultsCommand { get; private set; } public ICommand WriteToEepromCommand { get; private set; } public BindingList AvailablePorts { get; private set; } public BindingList AvailableBaudRates { get; private set; } public enum SessionStates { Disconnected, Connecting, Connected, } public SessionStates ConnectionState { get { return _connectionState; } set { if (_connectionState != value) { _connectionState = value; IsConnected = _connectionState == SessionStates.Connected; FirePropertyChanged("ConnectionState"); } } } // provided for convenience for binding set from the session state prop public bool IsConnected { get { return _isConnected; } private set { if (_isConnected != value) { _isConnected = value; FirePropertyChanged("IsConnected"); } } } public string SelectedPort { get { return _selectedPort; } set { if (_selectedPort != value) { _selectedPort = value; FirePropertyChanged("SelectedPort"); } } } public int SelectedBaudRate { get { return _selectedBaudRate; } set { if (_selectedBaudRate != value) { _selectedBaudRate = value; FirePropertyChanged("SelectedBaudRate"); } } } public void Connect() { _comms.CommPort = SelectedPort; _comms.BaudRate = SelectedBaudRate; // Todo: check the status of this call success/failure if (!_comms.Connect()) { ConnectionState = SessionStates.Disconnected; ApmVersion = "Error"; return; } ConnectionState = SessionStates.Connecting; _connectionAttemptsTimer = new Timer(); _connectionAttemptsTimer.Tick += _connectionAttemptsTimer_Tick; _connectionAttemptsTimer.Interval = 1000; //milliseconds _connectionAttemptsTimer.Start(); } void _connectionAttemptsTimer_Tick(object sender, EventArgs e) { if (_connectionState != SessionStates.Connecting) { _connectionAttemptsTimer.Stop(); return; } _comms.Send("X"); // once we connected, then get the version string _comms.Send("!"); } public void Disconnect() { _comms.Send("X"); _comms.DisConnect(); ConnectionState = SessionStates.Disconnected; } public string ApmVersion { get { return _apmVersion; } private set { if (_apmVersion != value) { _apmVersion = value; FirePropertyChanged("ApmVersion"); } } } public BindingList MonitorVms { get; private set; } public string Name { get { return "Arducopter Config"; } } public void Activate() { throw new System.NotImplementedException(); } public void DeActivate() { throw new System.NotImplementedException(); } public event EventHandler updatedByApm; public void Select(IPresentationModel vm) { if (_selectedVm==vm) return; if (vm == null) throw new ArgumentNullException("vm"); if (_selectedVm!=null) _selectedVm.DeActivate(); _selectedVm = vm; _selectedVm.Activate(); } public void handleLineOfText(string strRx) { throw new System.NotImplementedException(); } public event EventHandler sendTextToApm; } }