/* * AP_VOLZ_PROTOCOL.cpp * * Created on: Oct 31, 2017 * Author: guy */ #include "AP_Volz_Protocol.h" #if AP_VOLZ_ENABLED #include #include #include #include #include // Extended Position Data Format defines -100 as 0x0080 decimal 128, we map this to a PWM of 1000 (if range is default) #define PWM_POSITION_MIN 1000 #define ANGLE_POSITION_MIN -100.0 #define EXTENDED_POSITION_MIN 0x0080 // Extended Position Data Format defines +100 as 0x0F80 decimal 3968, we map this to a PWM of 2000 (if range is default) #define PWM_POSITION_MAX 2000 #define ANGLE_POSITION_MAX 100.0 #define EXTENDED_POSITION_MAX 0x0F80 #define UART_BUFSIZE_RX 128 #define UART_BUFSIZE_TX 128 extern const AP_HAL::HAL& hal; const AP_Param::GroupInfo AP_Volz_Protocol::var_info[] = { // @Param: MASK // @DisplayName: Channel Bitmask // @Description: Enable of volz servo protocol to specific channels // @Bitmask: 0:Channel1,1:Channel2,2:Channel3,3:Channel4,4:Channel5,5:Channel6,6:Channel7,7:Channel8,8:Channel9,9:Channel10,10:Channel11,11:Channel12,12:Channel13,13:Channel14,14:Channel15,15:Channel16,16:Channel17,17:Channel18,18:Channel19,19:Channel20,20:Channel21,21:Channel22,22:Channel23,23:Channel24,24:Channel25,25:Channel26,26:Channel27,28:Channel29,29:Channel30,30:Channel31,31:Channel32 // @User: Standard AP_GROUPINFO("MASK", 1, AP_Volz_Protocol, bitmask, 0), // @Param: RANGE // @DisplayName: Range of travel // @Description: Range to map between 1000 and 2000 PWM. Default value of 200 gives full +-100 deg range of extended position command. This results in 0.2 deg movement per US change in PWM. If the full range is not needed it can be reduced to increase resolution. 40 deg range gives 0.04 deg movement per US change in PWM, this is higher resolution than possible with the VOLZ protocol so further reduction in range will not improve resolution. Reduced range does allow PWMs outside the 1000 to 2000 range, with 40 deg range 750 PWM results in a angle of -30 deg, 2250 would be +30 deg. This is still limited by the 200 deg maximum range of the actuator. // @Units: deg AP_GROUPINFO("RANGE", 2, AP_Volz_Protocol, range, 200), AP_GROUPEND }; // constructor AP_Volz_Protocol::AP_Volz_Protocol(void) { // set defaults from the parameter table AP_Param::setup_object_defaults(this, var_info); } void AP_Volz_Protocol::init(void) { if (uint32_t(bitmask.get()) == 0) { // No servos enabled return; } AP_SerialManager &serial_manager = AP::serialmanager(); port = serial_manager.find_serial(AP_SerialManager::SerialProtocol_Volz,0); if (port == nullptr) { // No port configured return; } // update baud param in case user looks at it serial_manager.set_and_default_baud(AP_SerialManager::SerialProtocol_Volz, 0, 115200); // Create thread to handle output if (!hal.scheduler->thread_create(FUNCTOR_BIND_MEMBER(&AP_Volz_Protocol::loop, void), "Volz", 1024, AP_HAL::Scheduler::PRIORITY_RCOUT, 1)) { AP_BoardConfig::allocation_error("Volz thread"); } } #if AP_SERVO_TELEM_ENABLED // Request telem data, cycling through each servo and telem item void AP_Volz_Protocol::request_telem() { // Request the queued item, making sure the servo is enabled if ((uint32_t(bitmask.get()) & (1U<set_flow_control(AP_HAL::UARTDriver::FLOW_CONTROL_RTS_DE); port->begin(baudrate, UART_BUFSIZE_RX, UART_BUFSIZE_TX); port->set_unbuffered_writes(true); // Calculate the amount of time it should take to send a command // Multiply by 10 to convert from bit rate to byte rate (8 data bits + start and stop bits) // B/s to s/B, 1000000 converts to microseconds, multiply by number of bytes // 6 bytes at 11520 bytes per second takes 520 us const uint16_t send_us = (sizeof(CMD) * 1000000 * 10) / baudrate; // receive packet is same length as sent, double to allow some time for the servo respond const uint16_t receive_us = send_us * 2; // This gives a total time of 1560us, message rate of 641 Hz. // One servo at 641Hz, two at 320.5 each, three at 213.7 each ect... // Note that we send a telem request every time servo sending is complete. This is like a extra servo. // So for a single servo position commands are at 320.5Hz and telem at 320.5Hz. while (port != nullptr) { // Wait the expected amount of time for the send and receive to complete so we don't step on the response hal.scheduler->delay_microseconds(send_us + receive_us); while (port->txspace() < sizeof(CMD)) { // Wait until there is enough space to transmit a full command hal.scheduler->delay_microseconds(100); } #if AP_SERVO_TELEM_ENABLED // Send a command for each servo, then one telem request const uint8_t num_servos = __builtin_popcount(bitmask.get()); if (sent_count < num_servos) { send_position_cmd(); sent_count++; } else { request_telem(); sent_count = 0; } { // Read in telem data if available WITH_SEMAPHORE(telem.sem); read_telem(); } #else // No telem, send only send_position_cmd(); #endif } } // Send postion commands from PWM, cycle through each servo void AP_Volz_Protocol::send_position_cmd() { // loop for all channels for (uint8_t i=0; i= ARRAY_SIZE(telem.data)) { // Invalid ID return; } switch (cmd.ID) { case CMD_ID::EXTENDED_POSITION_RESPONSE: // Map back to angle telem.data[index].angle = linear_interpolate(ANGLE_POSITION_MIN, ANGLE_POSITION_MAX, UINT16_VALUE(cmd.arg1, cmd.arg2), EXTENDED_POSITION_MIN, EXTENDED_POSITION_MAX); break; case CMD_ID::CURRENT_RESPONSE: // Current is reported in 20mA increments (0.02A) telem.data[index].primary_current = cmd.arg1 * 0.02; telem.data[index].secondary_current = cmd.arg2 * 0.02; break; case CMD_ID::VOLTAGE_RESPONSE: // Voltage is reported in 200mv increments (0.2v) telem.data[index].primary_voltage = cmd.arg1 * 0.2; telem.data[index].secondary_voltage = cmd.arg2 * 0.2; break; case CMD_ID::TEMPERATURE_RESPONSE: // Temperature is reported relative to -50 deg C telem.data[index].motor_temp_deg = -50 + cmd.arg1; telem.data[index].pcb_temp_deg = -50 + cmd.arg2; break; default: // This should never happen return; } telem.data[index].last_response_ms = AP_HAL::millis(); } // Return true if the given ID is a valid response bool AP_Volz_Protocol::is_response(uint8_t ID) const { switch(ID) { case (uint8_t)CMD_ID::EXTENDED_POSITION_RESPONSE: case (uint8_t)CMD_ID::CURRENT_RESPONSE: case (uint8_t)CMD_ID::VOLTAGE_RESPONSE: case (uint8_t)CMD_ID::TEMPERATURE_RESPONSE: return true; default: break; } return false; } void AP_Volz_Protocol::read_telem() { // Try and read data a few times, this could be a while loop, using a for loop gives a upper bound to run time for (uint8_t attempts = 0; attempts < sizeof(telem.cmd_buffer) * 4; attempts++) { uint32_t n = port->available(); if (n == 0) { // No data available return; } if (telem.buffer_offset < sizeof(telem.cmd_buffer)) { // Read enough bytes to fill buffer ssize_t nread = port->read(&telem.cmd_buffer.data[telem.buffer_offset], MIN(n, unsigned(sizeof(telem.cmd_buffer)-telem.buffer_offset))); if (nread <= 0) { // Read failed return; } telem.buffer_offset += nread; } // Check for valid response start byte if (!is_response(telem.cmd_buffer.data[0])) { // Search for a valid response start byte uint8_t cmd_start; for (cmd_start = 1; cmd_start < telem.buffer_offset; cmd_start++) { if (is_response(telem.cmd_buffer.data[cmd_start])) { // Found one break; } } // Shift buffer to put start on valid byte, or if no valid byte was found clear const uint8_t n_move = telem.buffer_offset - cmd_start; if (n_move > 0) { // No need to move 0 bytes memmove(&telem.cmd_buffer.data[0], &telem.cmd_buffer.data[cmd_start], n_move); } telem.buffer_offset = 0; // Since the buffer is the same length as a full command, we can never get a valid packet after shifting // Always need to read in some more data continue; } if (telem.buffer_offset < sizeof(telem.cmd_buffer)) { // Not enough data to make up packet continue; } // Have valid ID and enough data, check crc if (UINT16_VALUE(telem.cmd_buffer.crc1, telem.cmd_buffer.crc2) != calculate_crc(telem.cmd_buffer)) { // Probably lost sync shift by one and try again memmove(&telem.cmd_buffer.data[0], &telem.cmd_buffer.data[1], telem.buffer_offset - 1); telem.buffer_offset -= 1; continue; } // Valid packet passed crc check process_response(telem.cmd_buffer); // zero offset and continue telem.buffer_offset = 0; } // Used up all attempts without running out of data. // Really should not end up here } #endif // AP_SERVO_TELEM_ENABLED // Called each time the servo outputs are sent void AP_Volz_Protocol::update() { if (!initialised) { // One time setup initialised = true; init(); } if (port == nullptr) { // no point if we don't have a valid port return; } // take semaphore and loop for all channels for (uint8_t i=0; iget_output_pwm(); servo_pwm[i] = (pwm == 0) ? c->get_trim() : pwm; } #if AP_SERVO_TELEM_ENABLED // Report telem data AP_Servo_Telem *servo_telem = AP_Servo_Telem::get_singleton(); if (servo_telem != nullptr) { const uint32_t now_ms = AP_HAL::millis(); WITH_SEMAPHORE(telem.sem); for (uint8_t i=0; i 5000)) { // Never seen telem, or not had a response for more than 5 seconds continue; } const AP_Servo_Telem::TelemetryData telem_data { .command_position = telem.data[i].desired_angle, .measured_position = telem.data[i].angle, .voltage = telem.data[i].primary_voltage, .current = telem.data[i].primary_current, .motor_temperature_cdeg = int16_t(telem.data[i].motor_temp_deg * 100), .pcb_temperature_cdeg = int16_t(telem.data[i].pcb_temp_deg * 100), .valid_types = AP_Servo_Telem::TelemetryData::Types::COMMANDED_POSITION | AP_Servo_Telem::TelemetryData::Types::MEASURED_POSITION | AP_Servo_Telem::TelemetryData::Types::VOLTAGE | AP_Servo_Telem::TelemetryData::Types::CURRENT | AP_Servo_Telem::TelemetryData::Types::MOTOR_TEMP | AP_Servo_Telem::TelemetryData::Types::PCB_TEMP }; servo_telem->update_telem_data(i, telem_data); } } #endif // AP_SERVO_TELEM_ENABLED } // Return the crc for a given command packet uint16_t AP_Volz_Protocol::calculate_crc(const CMD &cmd) const { uint16_t crc = 0xFFFF; // calculate Volz CRC value according to protocol definition for(uint8_t i=0; i<4; i++) { // take input data into message that will be transmitted. crc = (cmd.data[i] << 8) ^ crc; for(uint8_t j=0; j<8; j++) { if (crc & 0x8000) { crc = (crc << 1) ^ 0x8005; } else { crc = crc << 1; } } } return crc; } // calculate CRC for volz serial protocol and send the data. void AP_Volz_Protocol::send_command(CMD &cmd) { const uint16_t crc = calculate_crc(cmd); // add CRC result to the message cmd.crc1 = HIGHBYTE(crc); cmd.crc2 = LOWBYTE(crc); port->write(cmd.data, sizeof(cmd)); } #endif // AP_VOLZ_ENABLED