/* APM_MS5611.cpp - Arduino Library for MS5611-01BA01 absolute pressure sensor Code by Jose Julio, Pat Hickey and Jordi Muñoz. DIYDrones.com This library is free software; you can redistribute it and/or modify it under the terms of the GNU Lesser General Public License as published by the Free Software Foundation; either version 2.1 of the License, or (at your option) any later version. Sensor is conected to standard SPI port Chip Select pin: Analog2 (provisional until Jordi defines the pin)!! Variables: Temp : Calculated temperature (in Celsius degrees * 100) Press : Calculated pressure (in mbar units * 100) Methods: init() : Initialization and sensor reset read() : Read sensor data and _calculate Temperature, Pressure and Altitude This function is optimized so the main host don´t need to wait You can call this function in your main loop Maximun data output frequency 100Hz It returns a 1 if there are new data. get_pressure() : return pressure in mbar*100 units get_temperature() : return temperature in celsius degrees*100 units get_altitude() : return altitude in meters Internal functions: _calculate() : Calculate Temperature and Pressure (temperature compensated) in real units */ #include #include "AP_Baro_MS5611.h" /* on APM v.24 MS5661_CS is PG1 (Arduino pin 40) */ #define MS5611_CS 40 #define CMD_MS5611_RESET 0x1E #define CMD_MS5611_PROM_Setup 0xA0 #define CMD_MS5611_PROM_C1 0xA2 #define CMD_MS5611_PROM_C2 0xA4 #define CMD_MS5611_PROM_C3 0xA6 #define CMD_MS5611_PROM_C4 0xA8 #define CMD_MS5611_PROM_C5 0xAA #define CMD_MS5611_PROM_C6 0xAC #define CMD_MS5611_PROM_CRC 0xAE #define CMD_CONVERT_D1_OSR4096 0x48 // Maximun resolution #define CMD_CONVERT_D2_OSR4096 0x58 // Maximun resolution uint32_t AP_Baro_MS5611::_s_D1; uint32_t AP_Baro_MS5611::_s_D2; uint8_t AP_Baro_MS5611::_state; long AP_Baro_MS5611::_timer; bool AP_Baro_MS5611::_sync_access; bool AP_Baro_MS5611::_updated; uint8_t AP_Baro_MS5611::_spi_read(uint8_t reg) { uint8_t dump; uint8_t return_value; uint8_t addr = reg; // | 0x80; // Set most significant bit digitalWrite(MS5611_CS, LOW); dump = SPI.transfer(addr); return_value = SPI.transfer(0); digitalWrite(MS5611_CS, HIGH); return return_value; } uint16_t AP_Baro_MS5611::_spi_read_16bits(uint8_t reg) { uint8_t dump, byteH, byteL; uint16_t return_value; uint8_t addr = reg; // | 0x80; // Set most significant bit digitalWrite(MS5611_CS, LOW); dump = SPI.transfer(addr); byteH = SPI.transfer(0); byteL = SPI.transfer(0); digitalWrite(MS5611_CS, HIGH); return_value = ((uint16_t)byteH<<8) | (byteL); return return_value; } uint32_t AP_Baro_MS5611::_spi_read_adc() { uint8_t dump,byteH,byteM,byteL; uint32_t return_value; uint8_t addr = 0x00; digitalWrite(MS5611_CS, LOW); dump = SPI.transfer(addr); byteH = SPI.transfer(0); byteM = SPI.transfer(0); byteL = SPI.transfer(0); digitalWrite(MS5611_CS, HIGH); return_value = (((uint32_t)byteH)<<16) | (((uint32_t)byteM)<<8) | (byteL); return return_value; } void AP_Baro_MS5611::_spi_write(uint8_t reg) { uint8_t dump; digitalWrite(MS5611_CS, LOW); dump = SPI.transfer(reg); digitalWrite(MS5611_CS, HIGH); } // The conversion proccess takes 8.2ms since the command bool AP_Baro_MS5611::_ready() { return ( ( millis() - _timer ) > 10 ); // wait for more than 10ms } // Public Methods ////////////////////////////////////////////////////////////// // SPI should be initialized externally void AP_Baro_MS5611::init( AP_PeriodicProcess *scheduler ) { pinMode(MS5611_CS, OUTPUT); // Chip select Pin digitalWrite(MS5611_CS, HIGH); delay(1); _spi_write(CMD_MS5611_RESET); delay(4); // We read the factory calibration C1 = _spi_read_16bits(CMD_MS5611_PROM_C1); C2 = _spi_read_16bits(CMD_MS5611_PROM_C2); C3 = _spi_read_16bits(CMD_MS5611_PROM_C3); C4 = _spi_read_16bits(CMD_MS5611_PROM_C4); C5 = _spi_read_16bits(CMD_MS5611_PROM_C5); C6 = _spi_read_16bits(CMD_MS5611_PROM_C6); //Send a command to read Temp first _spi_write(CMD_CONVERT_D2_OSR4096); _timer = millis(); _state = 1; Temp=0; Press=0; scheduler->register_process( AP_Baro_MS5611::_update ); } // Read the sensor. This is a state machine // We read one time Temperature (state=1) and then 4 times Pressure (states 2-5) // temperature does not change so quickly... void AP_Baro_MS5611::_update(void) { if (_sync_access) return; if (_state == 1){ if (_ready()){ _s_D2 = _spi_read_adc(); // On state 1 we read temp _state++; _spi_write(CMD_CONVERT_D1_OSR4096); // Command to read pressure _timer = millis(); } }else{ if (_state == 5){ if (_ready()){ _s_D1 = _spi_read_adc(); _state = 1; // Start again from state = 1 _spi_write(CMD_CONVERT_D2_OSR4096); // Command to read temperature _timer = millis(); _updated = true; // New pressure reading } }else{ if (_ready()){ _s_D1 = _spi_read_adc(); _state++; _spi_write(CMD_CONVERT_D1_OSR4096); // Command to read pressure _timer = millis(); _updated = true; // New pressure reading } } } } uint8_t AP_Baro_MS5611::read() { _sync_access = true; bool updated = _updated; _updated = 0; if (updated > 0) { D1 = _s_D1; D2 = _s_D2; _raw_press = D1; _raw_temp = D2; } _sync_access = false; _calculate(); return updated ? 1 : 0; } // Calculate Temperature and compensated Pressure in real units (Celsius degrees*100, mbar*100). void AP_Baro_MS5611::_calculate() { int32_t dT; long long TEMP; // 64 bits long long OFF; long long SENS; long long P; // Formulas from manufacturer datasheet // TODO: optimization with shift operations... (shift operations works well on 64 bits variables?) // We define parameters as 64 bits to prevent overflow on operations dT = D2-((long)C5*256); TEMP = 2000 + ((long long)dT * C6)/8388608; OFF = (long long)C2 * 65536 + ((long long)C4 * dT ) / 128; SENS = (long long)C1 * 32768 + ((long long)C3 * dT) / 256; /* if (TEMP < 2000){ // second order temperature compensation long long T2 = (long long)dT*dT / 2147483648; long long Aux_64 = (TEMP-2000)*(TEMP-2000); long long OFF2 = 5*Aux_64/2; long long SENS2 = 5*Aux_64/4; TEMP = TEMP - T2; OFF = OFF - OFF2; SENS = SENS - SENS2; } */ P = (D1*SENS/2097152 - OFF)/32768; Temp = TEMP; Press = P; } int32_t AP_Baro_MS5611::get_pressure() { return(Press); } int16_t AP_Baro_MS5611::get_temperature() { return(Temp); } // Return altitude using the standard 1013.25 mbar at sea level reference float AP_Baro_MS5611::get_altitude() { float tmp_float; float Altitude; tmp_float = (Press / 101325.0); tmp_float = pow(tmp_float, 0.190295); Altitude = 44330 * (1.0 - tmp_float); return (Altitude); } int32_t AP_Baro_MS5611::get_raw_pressure() { return _raw_press; } int32_t AP_Baro_MS5611::get_raw_temp() { return _raw_temp; }