# SITL-on-HW notes ## Compiling and flashing Run the sitl-on-hw.sh script to compile and flash for MatekH743. Adjust for your own board if required before running. This script will configure a build ready for running SITL-on-hardware and attempt to upload it to a connected board. It includes a set of embedded parameters to configure the simulated sensors appropriately. :: cd $HOME/ardupilot ./libraries/SITL/examples/on-hardware/sitl-on-hw.sh Plane can also be simulated: :: cd $HOME/ardupilot ./libraries/SITL/examples/on-hardware/sitl-on-hw.sh -v plane ## Configuring Wipe the parameters on the board; this can be done with a mavlink command, or by setting the FORMAT_VERSION parameter to 0. For example: :: STABILIZE> wipe_parameters IREALLYMEAANIT STABILIZE> Got COMMAND_ACK: PREFLIGHT_STORAGE: ACCEPTED AP: All parameters reset, reboot board reboot You may need to power-cycle the board at this point. :: Device /dev/serial/by-id/usb-ArduPilot_MatekH743_3A0019001051393036353035-if00 reopened OK link 1 OK heartbeat OK disabling flow control on serial 2 AP: Calibrating barometer AP: Barometer 1 calibration complete AP: Barometer 2 calibration complete Init Gyro** AP: ArduPilot Ready Suggested EK3_BCOEF_* = 16.288, EK3_MCOEF = 0.208 Home: -35.36326 149.1652 alt=584.0000m hdg=353.0000 Smoothing reset at 0.001 AP: RCOut: PWM:1-13 AP: GPS 1: detected as SITL at 115200 baud Time has wrapped Time has wrapped 5577 368458 AP: EKF3 IMU0 initialised AP: EKF3 IMU1 initialised AP: EKF3 IMU0 tilt alignment complete AP: EKF3 IMU1 tilt alignment complete AP: EKF3 IMU1 MAG0 initial yaw alignment complete AP: EKF3 IMU0 MAG0 initial yaw alignment complete AP: PERF: 0/3999 [2653:2349] F=400Hz sd=39 Ex=0 AP: EKF3 IMU1 forced reset AP: EKF3 IMU1 initialised AP: EKF3 IMU0 forced reset AP: EKF3 IMU0 initialised AP: EKF3 IMU1 tilt alignment complete AP: EKF3 IMU0 tilt alignment complete AP: EKF3 IMU1 MAG0 initial yaw alignment complete AP: EKF3 IMU0 MAG0 initial yaw alignment complete AP: PreArm: 3D Accel calibration needed AP: PERF: 0/4000 [2631:2369] F=400Hz sd=5 Ex=0 AP: EKF3 IMU0 origin set AP: EKF3 IMU1 origin set AP: PERF: 0/4000 [2639:2362] F=400Hz sd=7 Ex=0 Force